Pacific Plumbing Supply Company
Company Logo
Home

All locations will be closed Tuesday, Dec 24th, Wednesday, Dec 25th and Wednesday, Jan 1st.

loading content
loading content
Watts

2 1/2" Cast Iron Double Check Valve Backflow Preventer Assembly, NRS Shutoff , Single Top Entry, ArmorTek Coating, Pressure-Sensing Test Cocks

2 1/2" Cast Iron Double Check Valve Backflow Preventer Assembly, NRS Shutoff , Single Top Entry, ArmorTek Coating, Pressure-Sensing Test Cocks
Watts

2 1/2" Cast Iron Double Check Valve Backflow Preventer Assembly, NRS Shutoff , Single Top Entry, ArmorTek Coating, Pressure-Sensing Test Cocks

ERP #WATT-88003376

MFR #88003376

UPC098268302356

Log In or Register for Product Pricing & Availability
Description

This 2 1/2" lead free double check valve backflow preventer assembly is designed to prevent the backflow of polluted water from entering into the potable water supply due to backsiphonage and or backpressure. Its compact modular design facilitates easy maintenance with a single access cover for in-line repairs. Ideal for protection in continuous pressure piping applications and cross-connections identified as non-health hazards. This assembly consists of an fused epoxy coated cast iron body, non-rising stem resilient seated gate valves, top mounted test cocks, two in-line independent positive seating check modules, captured springs, and replaceable check discs and seats. This assembly features integrated pressure-sensing test cocks that measure pressure fluctuations at three points on the backflow preventer when activated with an add-on monitoring connection kit. The kit collects, converts, and transmits the data values for use in a building management system. The coating on this backflow assembly uses ArmorTek technology to resist corrosion due to microbial induced corrosion (MIC) or exposed metal substrate.

  • Pressure sensors integrated on the backflow preventer to measure pressure fluctuations at three test cock locations when activated
  • Add-on kit available for transmitting data values to a building management system
  • A solution for monitoring assembly performance between code testing
  • Data access to help drive scheduling of maintenance and repair
  • Utilizes advanced ArmorTek coating technology to resist corrosion of internals
  • Compact design
  • Replaceable seats and seat discs
2 1/2" Cast Iron Double Check Valve Backflow Preventer Assembly, NRS Shutoff , Single Top Entry, ArmorTek Coating, Pressure-Sensing Test Cocks
2 1/2" Cast Iron Double Check Valve Backflow Preventer Assembly, NRS Shutoff , Single Top Entry, ArmorTek Coating, Pressure-Sensing Test Cocks
Watts
MFR #88003376